Corrosion

News Articles


Corrosion

NO Image:
06
X. Shan and J. H. Payer
One important factor affecting crevice corrosion of passive metals is the crevice geometry, e.g., the gap of the crevice. The crevice geometry can be affected by the properties of the materials used as the crevice formers, i.e., a polymeric crevice former can conform to the surface roughness of a m ... [Corrosion 66, 105005 (2010)] published Fri Oct 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
06
S. -W. Kim, H. -P. Kim, and J. -U. Jeong et al.
The present article is concerned with the effect of a residual stress induced by a dissimilar metal welding on stress corrosion cracking (SCC) of an Alloy 600 (UNS N06600) bottom-mounted instrumentation nozzle as a penetration mock-up in a pressurized water reactor. From a finite element analysis ( ... [Corrosion 66, 106001 (2010)] published Fri Oct 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
06
M. Rajc̆ić-Vujasinović, S. Nestorović, and V. Grekulović et al.
The CuAg4at% alloy exhibits the anneal-hardening effect, which has been seen in previous investigations in both cast and sintered CuAg4at% alloys. The goal of this work was to study corrosion properties of the cast alloy in different stages of its synthesis and thermomechanical treatment. The elect ... [Corrosion 66, 105004 (2010)] published Fri Oct 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
06
D. G. Enos
The current level of understanding of the atmospheric environmental degradation of gold-plated copper with and without a nickel underplate (and related materials) has limited the effectiveness of mathematical models aimed at predicting device lifetime/reliability. Efforts to understand this phenome ... [Corrosion 66, 105003 (2010)] published Fri Oct 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
06
Y. Wang and K. J. KarisAllen
Physical scale modeling (PSM) is an experimental technology that has been used to evaluate and design shipboard impressed current cathodic protection (ICCP) systems by various researchers and designers. PSM is also a preferred tool for validating ICCP numerical modeling results, owing to the well-c ... [Corrosion 66, 105001 (2010)] published Fri Oct 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
01
F. M. Song
Soil seasonal change is believed to be one of the major factors that contribute to high-pH stress corrosion cracking (SCC) of underground pipelines, although the specific role and mechanisms of the soil seasonal change in the SCC susceptibility are not clearly understood. This study is directed at ... [Corrosion 66, 095004 (2010)] published Wed Sep 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
01
J. Han, B. N. Brown, and S. Nes̆ić et al.
Localized carbon dioxide (CO2) corrosion is the most dangerous type of internal corrosion to mild steel pipelines in the oil and gas industry since the penetration rate of localized corrosion can be one or more magnitudes higher than that of uniform corrosion. In this study, the focus is on propaga ... [Corrosion 66, 095003 (2010)] published Wed Sep 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
01
F. Presuel-Moreno and W. H. Hartt
In a previous paper (Part I), the utility of Zn-submerged bulk anodes (ZnSBA) for providing cathodic protection to the above-waterline portion of a marine-reinforced concrete bridge substructure was investigated. It was determined that polarizations greater than 100 mV reached to the top of cast-in ... [Corrosion 66, 096001 (2010)] published Wed Sep 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
01
K. T. Chiang and L. Yang
Electrochemical sensors incorporating diamond-like carbon (DLC)-coated electrodes are effective tools for online, real-time corrosion monitoring at high temperatures. A vacuum-based chemical vapor deposition process was used to deposit a DLC thinfilm coating on the surface of the sensing electrodes ... [Corrosion 66, 095002 (2010)] published Wed Sep 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
01
K. N. Allahar, V. Upadhyay, and G. P. Bierwagen et al.
The non-conventional accelerated alternating current-direct current-alternating current (AC-DC-AC) testing method for organic coatings induces degradation by promoting cathodic reactions at the metal coating interface and ionic transport in the bulk of the coating. This cyclic method involves a tes ... [Corrosion 66, 095001 (2010)] published Wed Sep 01, 2010.

[Read the rest of this article...]

Posted in: Corrosion
Actions: E-mail | Permalink |
Page 14 of 18First   Previous   9  10  11  12  13  [14]  15  16  17  18  Next   Last